35

• Outdoor Sensor, if used.

A. Provided with boiler.

B. Locate outdoor sensor to protect against wind and

direct sunlight. Mounting instructions provided with

sensor.

C. Maximum wire length is 100 ft (30m) for 22 ga.

wire, or 150 ft (45m) for 18 ga. wire.

D. Connect wires to OUTDOOR SENSOR terminals.

Wires are interchangeable.

• System Sensor (Multiple boiler applications only)

• Domestic Hot Water (DHW) Thermostat, if used.

A. Use temperature control with dry contacts rated

at 0.5 amps @ 120 VAC. Boiler control does not

provide power to DHW temperature control.

NOTICE

IMPORTANT: Do not apply power to DHW T-T

terminals. Dry contact only, use of isolation relay

may be necessary.

B. Maximum wire length is 330 ft (100m) 22 gauge

wire.

C. Connect wires (interchangeable) to DHW T-T

terminals. Wires are interchangeable.

• Central Heating Thermostat

A. Use thermostat or boiler system control with dry

contacts related 0.5 amps @ 120 VAC.

Boiler

control does not provide 24 VAC power to central

heating thermostat.

B. Locate and install thermostat per manufacturer's

instructions. Maximum wire length is

330 ft (100m)

for 22 ga. wire.

C. Connect wires to CH T-T terminals. Wires are

interchangeable.

FIGURE

8-4

External Connections

(Do not apply external voltage to external terminals.)

NOTICE

Use dry contact for wires to CH T-T terminal and

DHW T-T terminal. E33 error code is displayed if

voltage is sent back to the control board. If error

is not corrected for extended period of time, this

voltage can permanently damage control board.

FIGURE

8-3

Isolation Relays for CH System Pump

and DHW Pump

8 - ELECTRICAL CONNECTIONS

DHW

Pump

CH

Pump

CH

Pump

Relay

120VAC

coil

DHW

Pump

Relay

120VAC

coil