3.1

Component Listing - Refer to diagrams on

following pages.

1.

User Interface Displays information regarding boiler

condition. Allows adjustment of boiler operating

parameters. NOTE: Does not replace thermostat used

to control central heating space.

2.

Combustion Air Inlet (2"/3") See section 6.

3.

Return Water From Heating System (In)

Connection supplied at bottom of boiler. See section 5.

4.

Low Voltage Terminal Strip Connection of all low

voltage wiring, including thermostat.

5.

Igniter

6.

Flame Sensor

7.

Sight Glass Permits observation of burner flame.

8.

Burner (see page 40)

9.

Heat Exchanger

10.

Condensate Collector

11.

Return Water Temperature Sensor

12.

Drain Valve (see page 14)

13.

Internal Primary Loop Ball Valve

14.

Supply Water Outlet to Heating System (Out)

Connections supplied for connecting from bottom of

boiler. See section 5.

15.

Vent Temperature Sensor

16.

Condensate Drain Boiler produces a liquid

(condensate) as a by-product of combustion. Condensate

must be piped to appropriate drain. See section 6.

17.

Heat Exchanger Pump

18.

Gas Shutoff Valve Fuel supply isolation during

servicing. See section 7

19.

Combustion Air Blower Delivers proper quantity of

combustion air, receives fuel from gas valve, mixes air

and fuel sending mixture to burner for combustion.

20.

Gas (Control) Valve Delivers proper quantity of fuel

to Combustion Air Blower. See section 7.

21.

Supply Water Temperature Sensor and High Limit

Switch

22.

Low Water Cutoff Senses inadequate quantity of

water. Turns off boiler before damage can occur.

23.

Safety Relief Valve Factory supplied, Field installed.

See section 5.

24.

High Voltage Junction Box For connection of 120V

components. See section 8.

25.

Vent Connector See section 6.

26.

Gas Connection See section 7.

27.

Wall Hanging Support Bracket (see page 12)

Integral to boiler. Allows wall mounting when used

with supplied wall mounting bracket. See section 4.

28.

Air Vent

29.

Boiler Control Module

30.

Lower Jacket Panel Gently pull upward then forward

to access.

31.

Transformer Supplies 24V power to low water cutoff.

32.

Flue Air Mixture Pressure Test Port - Not available

on all models.

33.

Combustion Analysis Test Port

34.

Internal Pump Relay - Not available on all models.

35.

Heat Exchanger Surface Temperature Switch

36.

ASME Plate

3 - COMPONENT LISTING