Appendix C - Dynamic Power Control

C-9

Configuration

Main DPC Menu

The main menu provides the basic configurable parameters: Enable DPC,

Target Eb/No, Speed Up Eb/No Range, and Target DPC Address. Each of these

main menu parameters are configurable from either the CLI or the Parameter

Editor, as shown in figure C-3 and figure C-4.
For simplicity, only CDM-IP menus are shown.

When using the CLI, select Dynamic Power Control from the main Vipersat

Configuration menu. When using the Parameter Editor, click on DPC from the

tree list.

Figure C-3 DPC Configuration screen, CLI

As can be seen, the Maximum Power is display only. The Margin is also display

only, as shown in these two figures. These parameter settings can only be

Calculate Max

Power

Calculate

Max Power;

Modulator

Calculate

Command

After entering all maximum budgetary settings,

this menu command will generate the Max

Power value for the modulator.

Max Power

Calculate

Max Power;

Modulator

Display

Only

The calculated modulator maximum Power at all

maximum settings (Data Rate, Code Rate,

Modulation, FEC Type). Controls upper limit of

modulator output power.

Table C-2 DPC Parameters, Calculate Max Power Menu

Parameter

Menu

Default

Description