Chapter 3 - Using the Web Server Interface (WSI)

3-33

Vipersat Configuration

A default value (65%) is provided, but if a different threshold is desired, an

alternate value can be specified by entering a value from 0–100% as shown in

figure 3-38.
Note that this value must be less than the value specified for the SCPC Step Up

Threshold.

Figure 3-38 SCPC Step Down Threshold field

SCPC Switch Delay

This menu item appears for Remote modems only.
The SCPC Switch Delay feature provides a switching delay period to ensure

that a premature switch up or down in the SCPC rate does not occur due to a

temporary rise or fall in traffic.
A default value (10 seconds) is provided, but this parameter can be modified by

entering a value from 0–50 seconds as shown in figure 3-39.

Figure 3-39 SCPC Switch Delay field

SCPC Step Up Excess

This menu item appears for Remote modems only.
During each SCPC Step Up switch, the excess capacity data rate value entered

by this command is added to the new SCPC data rate. This excess is added each

time an SCPC Step Up switch occurs. This setting makes additional bandwidth

available for when the demand arises while minimizing Step Up switching

events.
A default value (10%) is provided, but this parameter can be modified by enter-

ing a value from 0–100% as shown in figure 3-40.

Figure 3-40 SCPC Step Up Excess field