62

PR-03 instruction manual

8.3.3 PR-03-A specifications

General specifications

General system specifications for a PR-03-A refractometer sensor

Refractive index range

R.I. 1.3100–1.5400 (hot water – 100 Brix)

Accuracy

R.I. ± 0.0002 (corresponds typically to ± 0.1% by weight).
Repeatability and stability correspond to accuracy.

Speed of response

1.2 s undamped

Damping time constant

Selectable up to 5 min

Process temperature

-20

C–130

C (-4

F–266

F)

Temperature compensation

Automatic

Ambient temperature

max. 45

C (113

F), min. -20

C (-4

F)

Humidity

20–100 %

Pollution degree

Degree 2

Process pressure

Sanitary clamp max. 15 bar (200 psi) at 20

C (70

F)/

9 bar (125 psi) at 120

C (250

F)

Recommended flow velocity

Above 1.5 m/s (5 ft/s)

Quality certificate

ISO 9001

Sensor

Meets the requirements of the 3-A Sanitary Standard 46-02

Wetted parts

AISI 316L stainless steel, prism gaskets Teflon

R

, prism spinel

Sensor weight

2.2 kg (5 lbs)

Sensor protection class

IP67, Nema 4X

Process connection

2 1/2" Sanitary clamp

Temperature measurement

Built-in Pt-100

Image detector

1024 pixel CCD-element

Light source

Light emitting diode (LED)

Indicating transmitter

See Chapter 9

Options

− External output unit, Section 4.2
− Relay units for prism wash/alarm, Section 4.1
− Prism wash nozzles for steam and hot water, Section 8.3.2
− Flow cells according to separate drawings available from K-Patents
− Stainless steel sensor housing

1.30

1.35

1.40

1.45

1.50

1.55

1.60

R.I.

40

0 10

20

30

50

60

70

80

BRIX

A62

Figure 8.2

Sanitary refractometer PR-03-A rangeability