Metro Mobile Computing Workstations MPE-7800 Series Nickel Metal Hydride Power Supply User Manual
Page 20
20
Metro
TM
MPE-7800 Series NiMH Power Supply Operations Manual Supplement
InterMetro Industries Corporation
Charge Status Seven (7) multi color LEDs (green, amber) located on the Remote Fuel Gauge
display the charging status of the NiMH power supply.
Fuel Gauge
Status
Battery is discharging under normal, mobile operation.
Example shown is down to about 50% charge remaining.
Low battery LED flashing: plug power supply into AC
immediately.
AC indicates the power supply is plugged into the wall
AC.
CH indicates the battery is charging.
The amber LEDs will turn on in sequence to indicate the
charging status.
Example shown is up to about 50% charged.
AC indicates the power supply is plugged into the wall
AC.
The Amber LEDs indicate the battery is fully charged.
Note that the CH LED is not lit because the battery is not
being charged since the cycle is complete.