MPE-7800 Series NiMH Power Supply Operations Manual Supplement, Doc. No. L01-504
55
InterMetro Industries Corporation
Easy-Clean
Metal Screen
Filter Cleaning
Perform the following procedure to access and clean the Easy-Clean
metal screen filter.
•
Clear the cables away from the Power Supply fan area to reach the
fan filter cover. In some cases the DC power cable may need to be
disconnected.
Power Supply Back View
•
To remove the fan filter assembly, grip the assembly handle between
the thumb and index finger of your right hand and lift up to release the
magnetic latching.
Grip filter assembly handle
Lift handle up
•
Pull out the filter assembly.
Fan Filter Assembly
DC Power
Connector
Fan Filter