Mpe-7800 power supply system installation – Metro Mobile Computing Workstations MPE-7800 Series Nickel Metal Hydride Power Supply User Manual

Page 37

Advertising
background image

Metro

TM

MPE-7800 Series NiMH Power Supply Operations Manual Supplement, Doc. No. L01-504

37

InterMetro Industries Corporation

MPE-7800 Power Supply System Installation

In general, the Metro

TM

MPE-7800 Series NiMH Power Supply is provided already installed on a

Metro

TM

Mobile Computing Workstation and is ready for use.

The MPE-7800 Series NiMH Power Supply can be retrofitted, replaced or installed new on a
Metro

TM

Mobile Computing Workstation. The power supply is self-contained and is attached

using the correct mounting hardware and cables on the bottom of the Metro

TM

Mobile

Computing Workstation base.

For additional help, contact InterMetro Customer Service.

Hardware Installation

Notice: The following mounting and removal procedures apply to the most recent version of

the MPE-7800 Series Power Supply for the Metro

TM

Mobile Computing Workstations.

Older versions employ stud mounting slots on the top of the unit instead of the bracket
system described below. For additional information and help, please contact
InterMetro Customer Service.

Mounting the MPE-7800 Power Supply

Caution:

For safety, only qualified service personnel should perform the following procedure
to mount the MPE-7800 Series Power Supply on the Metro

TM

Mobile Computing

Workstations.

To mount the MPE-7800 Series Power Supply to the workstation base as a new or replacement
to an existing power supply, perform the following steps:

Notice: All handle brackets, screws and other hardware used in this procedure are usually

taken from a previous power supply mounted on the workstation. If replacement
hardware is needed, please contact InterMetro Customer Service.

1.

Attach two handle brackets, one on each side of the power supply using three 8-32 pan
head screws. Be sure to put the right-hand bracket on the right side and left-hand on the
left side (the ramp tabs should be at the low end of the slant and to the outside).

2.

Facing the back of the workstation, align the handle brackets inside the power supply
mounts on the bottom of the workstation base. Lift the power supply up and move
toward the front of the workstation, sliding the handle brackets up the ramp of the
mounts, until the tabs on lower ends of the brackets drop and catch in the slots on the
mounts.

3.

Secure each side with two 8-32 pan head screws.

4.

Connect all cables: DC Power connector, RJ45 cable to the Gauge port, USB to the
USB-B port (If provided. Notice: USB connection is required for use with BatteryPro)
and AC cable. Secure the AC cable with the clamp to the ground stud on the back of the
power supply.

Advertising