74

10. REASSEMBLY

10.1 Removal of Unit

• Reassemble the unit in the reverse order of removal. Described below are the parts that require

special care in reassembling the unit. Perform all wiring or rewiring as referenced in the wiring

diagram.

10.2 Compressor Mounting

• Mount the compressor on the frame, using

cushions, steel collars, spring washers, plate

washers and nuts.

10.3 Blower Assembly

1) Install blower fan for evaporator. Allow a

clearance of 0.12 in (3 mm) (minimum) on each

side of the evaporator fan.

CAUTION

• Tightening torque:

- 10.84 ± 2.17 ft•lbf (15 ± 2.7 N•m)

2) Install blower fan for condenser. Allow a

clearance of 0.12 in (3 mm) (minimum) on each

side of the condenser fan.

CAUTION

• Tightening torque:

- 10.84 ± 2.17 ft•lbf (15 ± 2.7 N•m)

I001818

Nut

Spring Washer

Steel Collar

Cushion

Plate Washer

I002229

Min 0.12 in
(3 mm)

Min 0.12 in
(3 mm)

<Evaporator Blower Assy>

I001947

Min
0.12 in (3 mm)

Min
0.12 in (3 mm)

<Condenser Blower Assy>

Advertising