ONICON F-2600 User Manual

Page 119

Advertising
background image

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]

F-2600 & F-2700 Vortex Flow Meter Manual 02/15 - 0808-7 / 19204

Page A-7

Output Signals

(1)

Analog: volumetric meter-field rangeable linear 4-20 mA output signal (1200

ohms maximum loop resistance) selected by user for mass flow rate or

volumetric

flow

rate.

Communications: HART, MODBUS-RTU, RS485, BACnet MS/TP

Multiparameter Meter: Up to three field rangeable linear 4-20 mA output

signals (1200 ohms maximum loop resistance) selected from the five

parameters mass flow rate, volumetric flow rate, temperature, pressure and

density.

Pulse: pulse output for totalization is a 50-millisecond duration pulse

operating a solid-state relay capable of switching 40 VDC, 40 mA maximum.


Note: (1) All outputs are optically isolated and require external power for

operation.

Alarms

Up to three programmable solid-state relays for high, low or window alarms

capable of switching 40 VDC, 40 mA maximum.

Totalizer

Based on user-determined flow units, six significant figures in scientific

notation. Total stored in non-volatile memory.

Wetted Materials

In-Line Flow Meter:

316L

stainless

steel

standard

C276 hastelloy or A105 carbon steel optional

Insertion

Flow

Meter:

316L

stainless

steel

standard

Teflon® packing gland below 500° F (260° C)

Graphite packing gland above 500° F (260° C)

Enclosure Protection

NEMA 4X and IP66 cast enclosure

Classification

Electrical Ports

Two 3/4" female NPT ports


Mounting Connections

In-Line: Wafer, 150, 300, 600 lb ANSI flange, PN16, PN40, PN64 flange

Insertion Hot Tap(1) Installation: 2" MNPT; 150, 300, 600 lb

ANSI flange, PN16, PN40, PN64 flange and optional retractor

with packing gland probe seal.

Note: (1) Removable under line pressure.

Mounting Position

In-Line Flow Meter: No effect.

Insertion Flow Meter: Meter must be perpendicular within ± 5° of the pipe

centerline.

Certifications

Material Certificate – US Mill certs on all wetted parts

Pressure

Test

Certificate

Certificate

of

Conformance

NACE

Certification

(MR0175)

Oxygen

Cleaning

(CGA

G-4.)

Advertising
This manual is related to the following products: