F-2600 & F-2700 Vortex Flow Meter Manual 02/15 - 0808-7 / 19204

Page 69

3.3.12 Calibration Menu

Password

ENTER

Use

keys to access menus.

Calibration

Menu

Meter Size

or Pipe ID

ENTER

Run Mode

Meter Factor

xxxx

Vortex Coef Ck

xx

Low Flow Cutoff

xx

Serial Number

xxxxxxxxx

F-2700 Series – meter size

F-2600 Series – pipe internal diameter (inches)

Meter calibration constant

– pulses / ft

3

– pulses / ft

Adaptive filter setting

Low Flow Cutoff

setting displayed

in volumetric flow

units (view only)

< Vol (xxx/xxx) >

xxx

< Mass (xxx/xxx)

xxx

Low Flow Cutoff

setting displayed

in mass flow

units (view only)

F-2700 Series

F-2600 Series

The Calibration Menu contains the calibration coefficients for the flow meter. These values
should be changed only by properly trained personnel. The Vortex Coef Ck and Low Flow
Cutoff are set at the factory. Consult the factory for help with these settings if the meter is
showing erratic flow rate.