Appendix d (quiet zone analysis), Std i2of5 warning qz/ss – RJS Inspector D4000 SP (FIRMWARE version A.06 and Later) User Manual

Page 45

Advertising
background image

Operator

’s Guide

Appendix D

002-5572

RJS, Minneapolis, MN

37

Appendix D (Quiet Zone Analysis)

Quiet Zone Analysis
The RJS Inspector D4000 trims data gathered during a
scan to approximately 10 times the X dimension on
each side of a bar code for all symbologies except
UPC and EAN. The areas are assumed to be quiet
zones and are included in the symbol analysis. If a low
reflectance object is detected in these areas the
screen displays:

Std I2of5
Warning QZ/SS


Quiet Zone Analysis for UPC and EAN symbols are
described in the following tables. In cases where an
addendum is included in the bar code, an addendum
gap analysis is also performed.

Table D-1 (Acceptable Parameters for Symbols
Without Addendums)

Symbology

Leading QZ

Trailing QZ

UPC-A

9X Minimum

9X Minimum

UPC-E

9X Minimum

7X Minimum

EAN-13

11X Minimum

7X Minimum

EAN-8

7X Minimum

7X Minimum

Table D-2 (Acceptable Parameters for Symbols With
Addendums)

Symbology

Leading QZ

Trailing QZ

GAP Size

UPC-A

9X Minimum

5X Minimum

9 - 12X

UPC-3

9X Minimum

5X Minimum

9 - 12X

EAN-13

11X Minimum

5X Minimum

7 - 10X

EAN-8

7X Minimum

5X Minimum

7 - 10X

Advertising
This manual is related to the following products: