Figure i-2 (code 3 of 9 passing) – RJS Inspector D4000 SP (FIRMWARE version A.06 and Later) User Manual

Page 59

Advertising
background image

Operator

’s Guide

Appendix I

002-5572

RJS, Minneapolis, MN

51

Figure I-2 (Code 3 of 9 Passing)

Inspector D4000L
Revision A.06
Cont. Scan Analysis
Code 3of9
Acceptable
*708101000021075
3*
#Decodes 011/012
%Decodes 091%
Ratio: 2.8 P
D/bility .62 A

-100% Tol. +100%
--RAR---++++++++

Continuous Mode

Enabled

During the time the

trigger was de-

pressed, 12 reads

were attempted and

11 of those were good

for a total of 91% of

the scans

Advertising