Element Reflectance Non-uniformity (ERN)

The reflectance difference between the highest
peak and lowest valley within each individual ele-
ment and quiet zone. When an element consists of
a single peak or valley, its element reflectance non-
uniformity is zero.


Element Width

The thickness or width of a bar or space as meas-
ured from its leading edge to its trailing edge.


Encoded Area

The total linear dimensional space taken by all
characters of a code pattern including start/stop
and data.


First Read Rate

The percentage of successful

“reads” of a

bar code

symbol on the first attempt.


Fixed Beam Scanner

A bar code reading device wherein coded items
pass across a stationary incandescent or LED light
source.


Flexo Film Master

A measurement standard symbol produced by
printing the symbol on clear plastic film using the
Flexographic printing process.


Gloss

A phenomenon related to the specular reflection of
incident light. The effect of gloss is to reflect more
of the incident light in a specular manner, and to
scatter less. This effect occurs at all angles of inci-
dence and should not be confused with the grazing
angle which is specular reflection often referred to
as sheen.