Super Systems 9210 Series User Manual

Page 18

Advertising
background image

M4557 - Model 9210 Nitriding Controller

SSi Manual SERIES 9210-M4557-Nitriding

Page 18 of 18

• The Alm Ack acknowledges any active alarm, in most cases it will be acknowledging

End of

Cycle

. The alarm must be acknowledged to allow the program to go to the next step, turning

EVENT 1 (End of Soak) Off, and stopping the program.

• The Esc button returns you to the default display screen.

Chart

The Chart display shows between 15 minutes

and 7 days of process variable data on the

screen, and can be scrolled back to view all of

the data stored on the hard drive (72 hours at a
time). The vertical timelines change as the time

changes on the screen. A chart is available for

the “LP1 and LP2” only and a chart is available

for the ”LP1 and LP2 plus their setpoints”. You

can toggle between the two charts by pressing

the Prev and Next keys. Note that LP1 relates
to %Dissocation/Kn and LP2 relates to the

Furnace Temperature.
The Prev and Next buttons change the display

from one chart to another (i.e. from just process

variables to process variables and setpoints.)
The blue Right and Left arrow buttons move the

displayed chart along the horizontal axis, going back and forward in time and then returning to real time.
The + and buttons change the time window displayed on the screen.
The Note key allows the operator to enter a note on the chart, similar to writing on a paper chart. The

note shows up when the chart is printed out using the utility software included with the Series 9200

instrumentation. The interface must be the Advantech 5.7 inch with the flash card.
Pressing the Note button displays an alpha/numeric keypad. Pressing the Edit button will allow the
operator to enter the ID/initials. Pressing the <- Enter button will set the entered text. Pressing the next

Edit button will allow the operator to enter the note. The operator can also determine where the note will

be written. The default choice is the current time and date. You can change the parameters and place the

note at whatever time and date is required. Pressing the Save button takes you back to the real time chart

page.
The View key allows you to look at the notes that have been stored with the chart.
The Realtime button will place the chart in realtime mode. Pressing the left or right arrows will take the

chart out of realtime.
The Esc button will return the operator to the main display screen.

Alarm Ack

The Alarm Ack button opens the Active Alarms screen and allows the operator to acknowledge any alarms

that have been configured, or that have been made part of the recipes that run on the Series 9210. If a

recipe has an alarm as a step, the alarm must be acknowledged before the recipe will continue from that

particular step.


Data Logging using Flash Card

Advertising