M4557 - Model 9210 Nitriding Controller

SSi Manual SERIES 9210-M4557-Nitriding

Page 43 of 43

• ATMOSPHERE, turns ON the atmosphere alarm and turns OFF the temperature alarm

• BOTH, turns ON both the temperature and the atmosphere alarms.

The band limit can be changed by the

SET_WAIT

opcode.

DOW_INQ

This opcode checks the real time clock for the day of the week. This is useful for performing

operations on a weekly basis on a specific day. The option data is the day of the week, i.e. SUN,
MON, TUE, WED, THU, FRI, and SAT.

EVT_IN

This opcode waits for an input event to be turned ON or OFF depending on the option value. The

option value is the event number followed by either ON or OFF.
If temperature data and or atmosphere data are specified, they are considered setpoints and will
be sent to the appropriate controller.

EVT_OUT

The

Event Output

opcode turns an output ON or OFF event based upon the option value. The

option value is the event number followed by either ON or OFF.
If temperature data and or atmosphere data are specified, they are considered setpoints and will

be sent to the appropriate controller.

G_SOAK

This is a guaranteed soak opcode. The temperature process value must be within the deviation

band to allow the soak timer to run. The option value is the soak time in hours and minutes. The

band limit can be changed by the

SET_WAIT

opcode. If Load TC Enable is set to ON, this opcode

will wait for all temperature inputs selected to be within the deviation band before starting the soak

timer.

GHSOAK

This is a guaranteed High soak opcode. The temperature process value must be within the

setpoint and the high deviation band range to allow the soak timer to run. The option value is the

soak time in hours and minutes. The band limit can be changed by the

SET_WAIT

opcode. If Load

TC Enable is set to ON, this opcode will wait for all temperature inputs selected to be within the

acceptable band before starting the soak timer.

GHZSOAK

This is a

Guaranteed Soak High

opcode for a zone. The temperature process value must be

above the deviation band to allow the soak timer to run. The option value is the soak time in hours

and minutes. The band limit can be changed by the

SET_WAIT

opcode.

GLSOAK

This is a guaranteed Low soak opcode. The temperature process value must be within the

setpoint and the low deviation band range to allow the soak timer to run. The option value is the

soak time in hours and minutes. The band limit can be changed by the

SET_WAIT

opcode. If Load

TC Enable is set to ON, this opcode will wait for all temperature inputs selected to be within the

acceptable band before starting the soak timer.

GLZSOAK

This is a

Guaranteed Soak Low

opcode for a zone. The temperature process value must be

below the deviation band to allow the soak timer to run. The option value is the soak time in hours

and minutes. The band limit can be changed by the

SET_WAIT

opcode.

GOSUB

The go to subroutine (recipe) opcode is used to call a program and then return to the calling

program. This is used to execute standard routines that can be used by many programs.

GOSUBs

can be stacked up to eight levels. The option data is the program number.

GRAMP

This opcode changes the temperature setpoint and/or the atmosphere setpoint linearly over time.

The option data is the total ramp time in hours and minutes. The temperature data specifies the

final setpoint for the temperature setpoint. The atmosphere data specifies the final value for the

atmosphere setpoint. This opcode will cause the setpoint change to wait until all temperature