M4557 - Model 9210 Nitriding Controller

SSi Manual SERIES 9210-M4557-Nitriding

Page 31 of 31

Loop 2 Dec

Loop 2 Combo

PV 3 retrans
Loop 3 Inc

Loop 3 Dec

Loop 3 Combo

Input 1 retrans

Input 2 retrans

Input 3 retrans
Input 4 retrans

The “Offset” selection will allow the user to set the offset. This will display a numeric keypad. This will

range from –9999 to 9999.

The “Range” selection will allow the user to set the range of the output. This will display a numeric

keypad. This will range from –9999 to 9999.

Pressing the Esc key returns you to the configuration menu.

Passcode and Alarm

Parameter Value
Level 1 Code

1

Level 2 Code

2

Web Level 1 Code

111

Web Level 2 Code

222

Web Change Enable

1

No Alarm

Contact is Open

Alarm Text Setup

Alarm 0 – Alarm 99

User Alarm xx

The values shown in the above table are the default values. The parameter “No Alarm” means that if there

is NO CONTROLLER ALARM, the controller alarm relay is NO. The “Level 1 Code” and the “Level 2 Code”

selections will allow the user to set the Supervisor and Administration passcodes, respectively. Either of
these options will display a numeric keypad that will range from 0 to 9999. The “Web Level 1 Code” and

the “Web Level 2 Code” selections will allow the user to set the Supervisor and Administration passcodes,

respectively, for the 9210’s web page. Either of these options will display a numeric keypad that will range

from 0 to 9999. The “Web Change Enable” selection will allow the user determine if changes can be made

to the instrument through the web page. This will display a numeric keypad that can be either 1 (Change
OK) or 0 (No Change Allowed). The “No Alarm” selection will allow the user to set what the no alarm state

is. This will display a numeric keypad that can be either 0 (Contact is Open) or 1 (Contact is Closed). This

allows the operator to assign the controller alarm as a NC contact such as a 1400°F alarm. The “Alarm

Text Setup” section will allow the user to set the alarm text for up to ninety-nine user alarms. Any of these

options will display an alphanumeric keypad.

Press the Esc key to return to the configuration menu.

IP Address

Parameter Value
IP Address 1

192

IP Address 2

168

IP Address 3

0

IP Address 4

200

IP Address Mask 1

255

IP Address Mask 2

255