Super Systems 9210 Series User Manual

Page 40

Advertising
background image

M4557 - Model 9210 Nitriding Controller

SSi Manual SERIES 9210-M4557-Nitriding

Page 40 of 40

Chapter 4 - PROGRAMS

Overview

The program format used in the SERIES 9210 provides a simple but powerful recipe language for

controlling the heat-treat process. The SERIES 9210 can store up to 300 programs of twenty-four

steps each. Each step consists of an opcode that defines what is done at this step. The step can

also contain atmosphere, temperature, and option data.
This enhanced step approach provides for shorter programs. For example, a complete boost

/diffuse program can be done in twenty-four steps.
The programmer also has alarm capability that can be turned on during a program to monitor

deviations and high and low limits while the program is running.

Program Editing

The program edit display is accessed through the Menu key on the default display screen. Pressing

the Menu key displays a screen that contains the configuration items that the operator is allowed

to perform. On that screen, running down the right side are five buttons. Below the blue down

arrow key is the Login key. Pressing this key displays a numeric keypad that allows you to enter

the passcode to get to the configuration level
(default as shipped from SSi is the number 1).

Pressing the number 1 and then pressing the

Enter button displays the many configuration

menu options, the first option is

Program Edit

.

Highlighting this parameter and pressing the

Enter key displays a numeric keypad that asks
you to enter the number of the program that

you wish to edit. Pressing that recipe number

and then pressing Enter displays that particular

recipe. You may have to clear the recipe number

that is shown in the display box if the number of
the recipe to be edited was not the last recipe

run on the system. Press the Clr button on the

numeric keypad and then enter the number for

the recipe that you wish to edit.

To edit a step in the recipe, use the up and

down arrow keys to highlight the step that you wish to edit and press the Enter key. This will
display the Step

Edit screen.

Highlighting the

parameter that

you wish to edit

and pressing the
Enter key takes

you to the

appropriate menu

- either that of

the Opcode

choices, or a numeric keypad to allow you to change the value.

Note: See

Chapter 5 – SERIES

9210 Opcodes

for a list of the opcodes

.

Advertising