Super Systems 9210 Series User Manual

Page 36

Advertising
background image

M4557 - Model 9210 Nitriding Controller

SSi Manual SERIES 9210-M4557-Nitriding

Page 36 of 36

The next screen is the Span Output 2 screen. This

screen will allow the user to set the span value for

Output 2. Measured at terminals 26(-) and 25(+) for
this step. The progress bar at the bottom of the

screen will display the calibration progress.


The next screen indicates that the calibration process is complete.

Full Calibration


This screen is used by SSi personnel, and it is a longer version of the

User Calibration

menu.

Set Menu Security

This menu allows the user to set the security level for all of the menu screens to one of three levels:

1. Operator – Lowest Level, No Pass code Required
2. Supervisor – Middle Level, Level 1 Pass code Required

3. Administrator – Highest Level, Level 2 Pass code Required.

The menu items with security levels are:

Menu

Item

Security

Level

Program

Edit

Supervisor

Auxiliary Instruments

Operator

Auxiliary Analog Input

Operator

Shutdown

Operator

9210 Date and Time

Supervisor

Slave Communications Status Supervisor
Manual Event Control

Supervisor

PID Loop Setup

Administrator

Event Run Program Setup

Administrator

Zone/Load TC Setup

Administrator

Port

Setup

Administrator

Instrument Setup

Administrator

Zone Assignments

Administrator

Furnace

Setup

Administrator

Default Wait Limits

Administrator

Furnace

Name

Administrator

Alarm

Setup

Administrator

Relay Assignments

Administrator

Relay

Setpoints

Administrator

Analog Input Setup

Administrator

Analog Output Setup

Administrator

Passcode and Alarm

Administrator

IP

Address

Administrator

Event

Control

Administrator

Valve Configuration

Administrator

Valve

Setup

Administrator

User

Calibration

Administrator

Edit

Span Output 2

Calibrate

<-- Back

Skip

Next -->

DONE

Enter measured output current (mA)

Advertising