Required tools – H3C Technologies H3C S12500 Series Switches User Manual

Page 144

Advertising
background image

134

Figure 101 Power strip with lightning protection

(1) Operating LED (green)

On means the circuit is operating correctly.

Off means the circuit is damaged.

(2) Grounding/pole detection LED
(red)

On indicates a wrong wire connection (the wire is not grounded or the live
line and null line are reversely connected), and you need to check the
power supply line.

(3) Power switch
(4) IEC standard socket

It is used to connect to the power supply in the equipment room through a
power cord.

(5) Overload automatic protector The protector automatically opens the electric circuit when the current

exceeds the threshold and closes the electric circuit when the current drops
below the threshold.

(6) Multifunctional socket

It is used to connect the power supply of the switch.

Installing a lightning protector for a network port

IMPORTANT:

Read the instructions for the lightning protector carefully before you install it.

If part of the network cable of a 10/100/1000 Mbps RJ-45 copper Ethernet port must be routed

outdoors, connect a lightning protector to the cable before you plug the cable into the port.
H3C recommends that you install a lightning protector for 10/100/1000 Mbps RJ-45 copper Ethernet

ports.
The switch does not come with any lightning protector.

Required tools

Phillips or flat-blade screwdriver

Multimeter

Tilted wire cutter

Advertising