Verification after power-on – H3C Technologies H3C S12500 Series Switches User Manual

Page 58

Advertising
background image

48

4.

Press Enter to begin configuring the switch at the prompt:

<Sysname>

NOTE:

The S12500 routing switches provide a command line interface (CLI). For more information about
the CLI, see

H3C S12500 Routing Switch Series Fundamentals Configuration Guide.

The output depends on your switch model.

Verification after power-on

H3C recommends that you check the following conditions after the switch is powered on:

The cooling system is operating. You should be able to hear fan rotation noise and feel air being

blown out.

All the system LEDs on the MPUs are functioning correctly.

Table 11 LED status when the S12504 operates correctly

Module LED

Status

MPU

SFC (red and green)

Flashing green

LC (red and green)

Flashing green

FAN (red and green)

Flashing green

PWR (red and green)

Flashing green

ACT (green)

Steady on

RUN (red and green)

Flashing green

LPU

RUN (red and green)

Flashing green

Switching fabric module RUN (red and green)

Flashing green

Power monitoring
module

RUN (green)

Steady on

MAJOR (red)

Off

MINOR (yellow)

Off

Fan

RUN (green)

Flashing

ALM (red)

Off

Table 12 LED status when the S12508/S12518 operates correctly

Module LED

Status

MPU

SFC (red and green)

Flashing green

LC (red and green)

Flashing green

FAN (red and green)

Flashing green

PWR (red and green)

Flashing green

ACT (green)

Steady on

RUN (red and green)

Flashing green

Advertising