Configuration procedure, Displaying the operating state of fans – H3C Technologies H3C S12500 Series Switches User Manual

Page 75

Advertising
background image

65

If a port is automatically shut down due to hardware failure protection, its status displayed with the

display interface command is Protect DOWN. To bring up the port, use the undo shutdown
command on the port.

If a card is isolated or its software is not allowed to be loaded due to hardware failure fix operations,
you can plug out the card and then plug it in to recover the card status.

After configuring in-service diagnosis and failure protection, you can use the display
hardware-failure-detection command to check the running information of the feature.

Configuration procedure

To configure in-service hardware failure diagnosis and failure protection:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enable in-service hardware
failure detection and

configure fix actions taken in

case of hardware failures.

hardware-failure-detection { chip |
board | forwarding } { off |

warning | reset | isolate }

Fix actions for hardware failures:

off—Takes no action.

warning—Sends warning

messages.

reset—Resets the failed card.

isolate—Shuts down the failed

port, isolates the failed card,

prohibits the failed card from

loaded, or powers off the failed
card to reduce the impact of the

failure to the system.

By default, the fix action taken for

all hardware failures is warning.

3.

Enable hardware failure
protection for aggregation

groups.

hardware-failure-protection
aggregation

Optional.
Disabled by default.
This command is effective only

when the fix action is configured as
isolate.

4.

Enter Ethernet interface view. interface interface-type

interface-number

N/A

5.

Configure hardware failure

protection for the port.

hardware-failure-protection
auto-down

Optional.
Disabled by default.
This command is effective only

when the fix action is configured as
isolate.

Displaying the operating state of fans

Use the display fan verbose command to display the operating state of fans on your switch.

In standalone mode:
# Display detailed information about all fans on the switch.

Advertising