Diagnosing transceiver modules – H3C Technologies H3C S12500 Series Switches User Manual

Page 81

Advertising
background image

71

Table 19 Command output

Field Description

Manu. Serial Number

Serial number generated during commissioning and testing of the transceiver
module

Manufacturing Date

Commissioning date

Diagnosing transceiver modules

The switch provides the alarm function and digital diagnosis function for transceiver modules. When a

transceiver module fails or is not operating correctly, you can check the alarms present on the transceiver

module to identify the fault source or examine the key parameters monitored by the digital diagnosis
function, including the temperature, voltage, laser bias current, TX power, and RX power.
To diagnose transceiver modules:

Task Command

Remarks

Display alarms present on the
transceiver in a specified
interface

display transceiver alarm interface
[ interface-type interface-number ]

If no error occurs, None is
displayed.

Display the present measured
values of the digital diagnosis

parameters for the transceiver

in a specified interface

display transceiver diagnosis
interface [ interface-type

interface-number ]

N/A

# Display the alarm information about the transceiver plugged in GigabitEthernet 3/0/1.

<Sysname> display transceiver alarm interface GigabitEthernet 3/0/1

GigabitEthernet3/0/1 transceiver current alarm information:

TX fault

Table 20

shows the alarm information that might occur to the commonly used transceivers.

Table 20 Command output

Field Remarks

SFP

RX loss of signal

Received signals are lost.

TX fault

Transmission error.

RX power high

The received optical power is high.

RX power low

The received optical power is low.

TX power high

The transmitted optical power is high.

TX power low

The transmitted optical power is low.

TX bias high

The transmitted bias current is high.

TX bias low

The transmitted bias current is low.

Temp high

The temperature is high.

Temp low

The temperature is low.