Rebooting your switch – H3C Technologies H3C S12500 Series Switches User Manual

Page 66

Advertising
background image

56

Field Description

Brd Type

Hardware type of a card, which can be:

Specific card model—Type of a card (such as LST1MRPNC1), which is the

same as the silkscreen.

NONE—No card is in the slot.

UNKNOWN—The card is not supported by the software version and thus

cannot start correctly.

Brd Status

Card status, which can be:

Absent—No card is in the slot.

Master—The card is an active processing unit (MPU).

Slave—The card is a standby MPU.

Normal—The card is an interface card and is operating correctly.

Fault—The card is starting or has failed.

Off—The card is not powered on.

Illegal—The card is not supported by the software version and cannot start

correctly.

Offline—The card is isolated.

Software Version

Software version of the current card:

Specific software version.

NONE—No card is in the slot.

Mismatched—The software version does not support the card and thus cannot

be uploaded.

Rebooting your switch

CAUTION:

Rebooting the switch interrupts network services.

To avoid configuration loss, use the save command to save the running configuration before a reboot.

Before a reboot, use the display startup and display boot-loader commands to verify whether you have
specified the correct startup configuration file and startup software images.

You can reboot the switch in one of the following ways:

Power off and then power on the switch. This method might cause data loss, and is the
least-preferred method.

Immediately reboot the switch at the CLI.

At the CLI, schedule a reboot to occur at a specific time and date or after a delay.

The first method is called "cold reboot" or "cold startup". The second and third methods are called

"warm reboot" or "warm startup", and can be used remotely.
For data security, if you reboot the switch while the switch is performing file operations, the switch does

not reboot.
The precision of the rebooting timer is 1 minute. One minute before the rebooting time, the switch

prompts "REBOOT IN ONE MINUTE" and reboots in one minute.
To reboot cards or switches immediately at the CLI:

Advertising