Max Count—Maximum number of messages that a queue can accommodate. The value 0

indicates that the flow control function is disabled. The value range is 0 to 150.

{

Queue-full Max Time(s)—Maximum time of period during which a queue keeps full. The value
0 indicates that the flow control function is disabled. The value range is 0 to 60.

2.

Click OK.

Viewing or configuring the 3Q protocol configurations

1.

In the XML Accounting Server page, click the 3Q Protocol Configuration tab.
3Q Protocol Configuration list contents

{

Data IP Address—IP address that receives the data packets.

{

Data Port—Port number that receives the data packets.

{

Control IP Address—IP address that receives the control packets.

{

Control Port—Port number that receives the control packets.

{

Protocol Status—Status of the current protocol. Options are Enabled and Disabled.

{

Client Thread—Number of the threads that receive data.

2.

Click OK.

Viewing BES common statistics

1.

In the XML Accounting Server page, click BES Common Statistics tab.
BES Common Statistics list contents

{

Total Incoming Requests—Total number of IP telephone call requests recorded in the VCX data
server.

{

Total Invalid Requests—Total number of invalid IP telephone call requests recorded in the VCX
data server.

{

Total Duplicate Requests—Total number of duplicate IP telephone call requests recorded in the

VCX data server.

{

Total Num of Responses—Total number of IP telephone call responses recorded in the VCX data
server.

{

Total Malformed Requests—Total number of incorrect IP telephone call requests recorded in the
VCX data server.

{

Total Packet Dropped—Total number of dropped packets recorded in the VCX data server.

{

Total Pending Requests—Total number of IP telephone call requests to be processed on the VCX
data server.

{

Total Unknown Types—Total number of IP telephone call requests of unknown types recorded in
the VCX data server.

{

Server Up Time (s)—Period of time from when the VCX server is enabled till now, in seconds.

2.

Click Cancel to return to the Voice Device Information page.

Viewing or modifying BES common configurations

1.

In the XML Accounting Server page, click the BES Common Configuration tab.

2.

View or modify the BES common configurations.

{

Client Activity Interval(millisecond)—Maximum time of period during which a client is inactive
but kept online. The default value is 200000 milliseconds. The value range is 2000 to

200000.