Removing zones (master & main codes only) – RISCO Group GT 600 User Manual

Page 12

Advertising
background image

Page

11

GT 600 601

User Manual

Removing Zones
(Master & Main codes only)

If programmed by the installation company individual zones may be removed, this may
only be done by a Master or Main level of code. If a zone has

not been programmed

as ‘Remove’ an error message will be displayed when trying to remove it. It should be
noted that if an Area Main code is being used, only zones associated with that
area may be removed.

1)

With the display showing:-

2)

Enter a Master or Main level code,
the display will show:-

3)

Press NO, the display will show:-

4)

Press YES, the display will show:-

5)

Enter the zone number you wish to
remove followed by YES (pressing
NO will 'un-remove' a zone), the
display will show:-

6)

Repeat step 5 until you have removed all
the required zones.

7)

Press 0 to escape, the display will show:-

8)

Press YES, the continuous exit tone will
sound.

9)

Exit the premises via the authorised
exit route ( the exit tone will change as detectors
are violated). When the premises are secure
listen that the exit tone returns to the continuous
tone. Wait until the exit tone finishes before leaving.

Note:

Zone remove is only effective for the one set.

01 JAN 18 : 58 : 01

Do you want to . .
SET the System ?

Do you want to . .
REMOVE Zones ?

Enter Zone No. - -
then + YES or - NO

Enter Zone No. - -
then + YES or - NO

Do you want to . .
SET the System ?

600 601 PR600601_1_10user.qxd 25/08/2010 11:53 Page 11