Page

101

GT490X Engineer’s Reference Guide

6 4 W

IRE

C

ONTOUR

RKP W

IRING

I

NFORMATION

Note: All keypads on the same system MUST be of the same type. i.e. All four wire or
all six.

Note: All Keypads MUST be connected before powering up the Control
Panel.

CPX

Keypad Connection Details

REMOTE KEYP

AD

D2 D1 0V 12V

KEYP

AD

CONNECTIONS

REMOTE

KEYPAD(S)

MAY BE WIRED

IN STAR OR

DAISYCHAIN

FORMAT

D2/B D1/A

0V 12V

Note: 680 Ohm resistor should

be fitted to ONE of the RKPs.

If RKPs are wired in daisy chain

this should be the last RKP in

the line,

Remove 2K2

if using Keypad

Zones and use

resistor EOL.

GTAG

PROXIMITY

READER(S)

4 Wire Contour RKP

A1 & A2, if used, are connected

to the first reader (antenna).

If using an second reader, remove

the link and connect between A3 & A4.

680 Ohm

2K2

Note: Both detectors must be run on a single cable

from the Keypad to the first detector

then the second. The 2K2 resistor must be in the

last/final detector.

Zone 12V 0V

D1

D2

3K3

2K2

5K6

Alarm N/C Tamper N/C

1st Detector

2nd Detector

+ Power -

Alarm N/C Tamper N/C

+ Power -

RKP

0V

D1

Zone 12V

D2

5K6

2K2

3K3

2nd Detector

Door Contact

Alarm N/C Tamper N/C

+ Power -

RKP

Alarm

Note: Keypad zones are

preset and cannot be changed.

E/E - 3K3 KP Zone 1

Part E/E - 5K6 KP Zone 2

EOL - 2K2

Keypad Zone Wiring Details

GT490X Keypad Connection Details

PR5851 Rev12 490X Eng Ref Guide.qxd 10/05/2012 11:33 Page 101