GT490X Engineer’s Reference Guide

Programming Panic

Note: Duress is defaulted to Off and cannot be changed. Duress 7 is now no
longer available
.

You should also check current legislation if Panic signals are allowed for the grade of
system that you are fitting.

1)

Enter into Engineer Mode
To do this follow Steps 1 to 4 on page 18
With the display showing:-

2)

Press No seven times. The display will show:-

3)

Press Yes. The display will show:-

It should be noted that with PA = Bells Only no PA signals will be sent to Central
Station.

Available setting for PA are

Bells Only

Activating a Panic will only sound the Bells.

Bells Always

Activating a Panic will Sound the Bells and send a signal
to Central Station provided that a Digi Channel is
programmed as Panic.

Silent Always

Activating a Panic will only send a signal to Central Station
providing that a Digi Channel has been programmed as
Panic.

Bells if LFlt

As Silent Always but will revert to Bells if a Linefault is
present.

Program . . . . _ _ _
Zones ?

Program . . . . _ _ _
Panic / Duress ?

PA = Bells Only

= Non-Testable