Programming alarm confirm – RISCO Group Gardtec 490X User Manual

Page 81

Advertising
background image

Page

80

GT490X Engineer’s Reference Guide

Programming Alarm Confirm

This section is used to program options that are relevant to BS8243. Before
programming these options please take time to read the following notes that will help in
your understanding of BS8243

All communications systems that require a Police URN will need to conform to
BS8243.

These notes intended as a guide only and should be read in conjunction with the
relevant standards relating to the alarm system giving particular attention to
EN50131-1and BS8243. These may be obtained from the British Standards Institute.

BS8243 options available are.

Confirm Time Window (default = 60)
This time window may be programmed between 1 and 120 minutes. To comply the
required time should be between 30 and 60 minutes.

Confirm on Entry (default = On)
This option may be programmed to On or Off. If Confirm on Entry = Off then confirmed
alarms to central station are disabled if the entry timer is started. If ACE or G-Tag is
used then it is permissible to set this option to On.

Sounder Mode (default = Unconfirmed)
This option controls the system speakers fitted, options are confirmed or un-confirmed.
If Sounder Trigger = Confirmed then internal sounder will only trigger with a confirmed
alarm.
If Sounder Trigger = Unconfirmed then internal sounders will trigger with un-confirmed
alarms.
This feature is not mandatory for BS8243

Reset Mode (default = Any)
Choose from Any or Normal.
If Unconfirm = Any then any code can be used to reset an un-confirmed alarm.
If Unconfirm = Normal then the programmed reset mode for alarm will still be required
i.e. if alarm reset has been programmed as engineer and Unconfirm reset is Normal
then an engineer reset will be required for Un-confirmed alarms.

Confirm Secondary Time Window (default = 60 minutes)
This time window may be programmed between 1 and 120 minutes we would suggest
a time between 30 and 60 minutes but should typically be the same time as the
confirm time window. This option affects zones that have been allocated as secondary
zones only. For functionality please refer to Secondary Zones Below.

PR5851 Rev12 490X Eng Ref Guide.qxd 10/05/2012 11:33 Page 80

Advertising