Programming pgm1 / custom – RISCO Group Gardtec 490X User Manual

Page 71

Advertising
background image

Page

70

GT490X Engineer’s Reference Guide

Programming PGM1 / Custom

PGM1 is located on the control panel PCB close to the Bell terminals.

Up to 8 custom outputs may be programmed on to PGM 1 to 3. A custom output may
be used so that the output can follow a zone or a user code.

1)

Enter into Engineer Mode
To do this follow Steps 1 to 4 on page 18
With the display showing:-

2)

Press No eleven times. The display will show:-

3)

Press Yes. The display will show:-

The options available for PGM1 are shown on page 62.

4)

Press No until the required setting is displayed
then press Yes. The display will show:-

With the PGM2 programmed as Bell the output will operate with the Bell when this is
set as +V. With this set as -V the output will be inverted e.g On, turning Off with the
Bell.

5)

Press No. until the required setting is displayed
then press Yes. The display will show:-

6)

Press No to change the Cus 1 to Zone, Code or
Group as required to follow. Press Yes.
The display will show:-

Program . . . . _ _ _
Zones ?

Program . . . . _ _ _
PGM1 / Custom ?

PGM1 O/P
= Pulse Off =+V

PGM1 O/P
= Pulse Off >+V

Cus 1 = Zone #=000
=Day = Fol+ t=00

Cus 1 = Zone #>000
=Day = Fol+ t=00

PR5851 Rev12 490X Eng Ref Guide.qxd 10/05/2012 11:33 Page 70

Advertising