GT490X Engineer’s Reference Guide

Keypad disabled for 90 seconds.
The keypad will monitor the number of attempts without a valid User Code being
entered. More than seven attempts will cause a keypad tamper and lock-out the
keypad for 90 seconds. This will be displayed as ‘LOCK-OUT Check’ and will require a
valid User Code entry to stop the sounders (only after 90 seconds). If the system was
Unset only the internal sounders will operate. If the system was Set a full alarm will be
generated.

Setting by digital key
Setting the system must be initiated from within the premises; when using a radio fob
interaction with the keypad will be required.
Setting the system with a Gtag fob must be from a keypad (not from a remote setting
point) to comply with the standards for monitored alarms.

Zones on soak test.
Zones that are put on test must be indicated to the user. When setting the system the
user must acknowledge this by pressing No.

Entry Procedure
As per BS8243 - 2010, Annex G.
A confirmed alarm may now be generated on entry by straying off from the entry route
into a normal alarm zone.

Engineer on site channel.
BS-EN50131 - 3 2006 plus A1 2009, as per 8.3.1.
When an Engineer code is entered a signal is sent to the ARC indicating an engineer
is on site.

New Fast format channels.
Engineer on site. (See page 50).
PA Confirm (See page 61).

New Contact ID and SIA triggers.
Engineer on site = Off/On. (See page 92).

New option for the reset modes.
Fault Reset = +Anti / Eng code / Anti code. (See page 66).