Page – RISCO Group Gardtec 490X User Manual

Page 12

Advertising
background image

Radio Zone Expander

One GardTec Radio Zone Expander may be fitted directly to the RS485 Bus connec-
tions on the control panel PCB without the need for any interface card. A Radio
Expander card will allow eight wireless zones & eight wireless Fobs.

Radio Zone Programming

When programming Radio Zones the zone numbering for the Radio Zones will start at
91. When programming Radio Fobs the numbering of the Fobs will start at 81.

Resistor Colour Codes

Page

11

GT490X Engineer’s Reference Guide

RS485 (RADIO EXP

ANDER)

CONNECTIONS

RS485

RED BLK

YEL
GRN

GRN

YEL

BLK RED

RADIO RECEIVER

KEY

ID

ZONE

ID

RECEIVER

DIP SWITCH

SETTINGS

1 2 3 4

ON

1 2 3 4

ON

RADIO EXPANDER WIRING & SWITCH SETTINGS

Blue
Grey
Red

Brown

6K8

Brown

Blue
Orange

Brown

16K

Red
Violet
Orange

Brown

27K

Yellow
Violet
Red

Brown

4K7

Brown
Red
Orange

Brown

12K

PR5851 Rev12 490X Eng Ref Guide.qxd 10/05/2012 11:32 Page 11