GT490X Engineer’s Reference Guide

Zone Types available are:-

12 Hour

Full Alarm if Control Panel is Set.

Access

Will allow to pass through on exit.
Will allow to pass through on entry only if E/E is opened first.

24 Hour

Internal Sounder if Unset.
Full alarm if Set.
Remains active in Engineer Programming Mode.

Entry/Exit (or E/E)

Zone used as last exit point (will terminate exit time if setting mode is set to
E/E or Time+E/E).
Will start E/E time if opened when Control Panel is Set

Part E/E

As Access if Control Panel is Full Set
As Entry/Exit if Control Panel is Part Set

Panic

24Hour Personal Attack (or Panic Attack). Active if Control Panel is Set,
Unset or in Engineer Programming Mode . May only be tested via Engineer
code if programmed as testable.

Alert

Internal Sounder Only, Recorded to Log when Unset
Recorded to Log when SET

Fire

Will give Fire alarm when activated (pulsed sounders) with Control Panel Set
or Unset.
Remains active in Engineer Programming Mode.

ET

Exit terminator. Used for final setting of the system. Exit Mode must be
programmed for ET.

Monitor

Will write to the log once only in any one set or unset unless chime is
allocated then all activations are written to the log.

KSW Bat

When used, zone should be connected to the trouble/status output of third
party radio equipment that is capable of giving a low battery signal.

Line Fault

When used, acts as a Line Fault input to the control panel.

Fault

When used, will act as an Fault input to the control panel when an internal
fault has been detected within the PIR.

Mask

When used, will act as an input to the control panel if the detector has been
blocked or covered.

Note: Fault and Mask are treated as 24Hr but trigger a Fault Sound in Day (Unset) Mode. The Fault
sound is a three tone sounder.