8 hot-swapping – PLANET NAS-3410 User Manual

Page 40

Advertising
background image

32

bad in the file system. All the newly added devices will be scanned before usage to ensure the

data integrity in the NAS Server.

Select the volumes or disks you want to scan, click Scan Now button to start scanning. Or, click

Schedule to set the time for NAS Server to perform scanning at the scheduled time.

Disk Auto-scanning

To make sure that the hard disks contain no bad sectors before putting into use, it is suggested to

perform disk-scanning before taking such actions as creating a volume, expanding a volume,

migrating data or assigning a hot-spare disks. If disk auto-scanning is enabled, the NAS server

can scan disks automatically when you perform these actions. If the hard disks have ever been

scanned in the last 30 days, the auto-scanning will be skipped so that the auto-scanning will not

be activated too often.

To enable the feature, please click the Configure hyperlink on the Volume

ÆScan page. Set the

Disk Auto-scanning item to Enabled.

5.8 Hot-swapping

You may have to change hard disks in some situations, such as hard disk failure, degraded RAID

or general maintenance. The NAS-3410 supports HDD hot swapping. Below are the instructions

of replacing hard disks.

1. Identify which hard disk fails. The amber LED of the HDD tray will blink to indicate hard disk

failure.

2. Turn off the failed HDD by pressing the red button on the HDD tray.

3. When the amber LED is steady on, it is ready for being unplugged. Unplug the HDD tray and

replace the HDD with a good one.

4. Plug in the HDD tray. Wait until the Green LED is steady on. Then you are done.

When a RAID volume is degraded and there is no available hot-spare disk for rebuilding, the

RAID volume will stay in the degraded state. In this state, you can hot-unplug the failed hard disk

and plug in a good one in the same HDD tray. The RAID volume will rebuild automatically with the

new hard disk.