10 Go/Nogo mode

Page 4

10.3.

Use of the frame

The comparison with the frame is used to stop the acquisition. This comparison will be made on the

Channels for Go/Nogo selected in the Trigger page.

The information window at the bottom of the Trigger page summarises the general
configuration of the acquisition:

-

channels and functions between channels validated for the acquisition

-

channels and functions between channels compared with the frame

-

number of dots per channel (according to the number of blocks)

-

total acquisition time (according to the acquisition rate)

-

position of the trigger (according to the pre-triggering)

The comparison with the frame can only be made when the channels have been
validated for the acquisition.
An error message will display when you have selected Channels for Go/Nogo that
have not been validated (ON).

The acquisition is made as previously (see chapter Memory mode).

When the memory block is full, the appliance will check that every collected dots on the frame
channels are the 2 min and max reference curves of the frame.

If every dots are within the frame, the acquisition will start again (in the same block). Else, the
acquisition will stop.