10.3.7.4

SCALER-AS

Functions

Permission

Transparency

Set:

SCLR-AS

End User

Public

Get:

SCLR-AS?

End User

Audio

Description

Syntax

Set:

Set the auto sync off timer

#

SCLR-AS

SPP1,P2CR

Get:

Get the auto sync off timer definition

#

SCLR-AS?

SPP1CR

Response

Set / Get: ~

nn@

SCLR-AS

SPP1,P2CR LF

Parameters

P1

*

(All)

P2

– For setting the auto sync timer:

0

(Disable),

1

(Fast, 10sec),

2

(Slow, 2min)

Response triggers

The auto-sync feature determines whether the outputs are turned off when no video is detected on the
selected input

Notes

All 4 scalers have the same auto sync off timer

K-Config Example

Set the auto sync off timer to slow:

“#SCLR

-AS *

,2”,0x0D

10.3.7.5

SHOW-OSD

Functions

Permission

Transparency

Set:

SHOW-OSD

End User

Public

Get:

SHOW-OSD?

End User

Public

Description

Syntax

Set:

Set the OSD of the selected channel

#

SHOW-OSD

SPP1,P2CR

Get:

#

SHOW-OSD?

SPp1CR

Response

Set / Get: ~

nn@

SHOW-OSD

SPP1,P2CR LF

Parameters

P1

*

(All)

P2

1

(Off),

1

(On)

Response triggers

Response is sent to the com port from which the Set (before execution) / Get command was received

After execution, response is sent to all com ports if

SHOW-OSD

was set any other external control device

(button press, device menu and similar) or genlock status was changed