1 mandatory system commands, Ion 10.3.1 – Kramer 4 x 4 Seamless AV Matrix Switcher/Multi-Scaler User Manual

Page 84

Advertising
background image

VSM-4x4A

VSM-4x4A RS-232/Ethernet Communication Protocol

77

Miscellaneous Commands (see Section

10.3.9

)

10.3.1

Mandatory System Commands

Command

Description

#

Protocol handshaking (system mandatory)

BUILD-DATE

Get device build date (system mandatory)

FACTORY

Reset to factory default configuration

HELP

Get command list (system mandatory)

MODEL

Get device model (system mandatory)

PROT-VER

Get device protocol version (system mandatory)

RESET

Reset device (system mandatory)

SN

Get device serial number (system mandatory)

VERSION

Get device firmware version (system mandatory)

10.3.1.1

#

Functions

Permission

Transparency

Set:

#

End User

Public

Get:

-

-

-

Description

Syntax

Set:

Protocol handshaking

#

CR

Get:

-

-

Response

~nn@

SP

OK

CR LF

Notes

Validates the Protocol 3000 connection and gets the machine number

Step-in master products use this command to identify the availability of a device

K-Config Example

“#”,0x0D