3-11. FILTERING

3.

Open door(s) under unit, and slowly turn drain

OF SHORTENING

valve handle a half turn. Leave for a few minutes, then

(Continued)

slowly, fully open drain valve. This prevents much

splashing of the hot shortening as it drains.

4.

As the shortening drains from the frypot, use brushes

to clean the sides of the frypot and the burner tubes or

heating elements. If the drain fills with breading, use

straight white brush to push excess breading into the filter

drain

pan.

5.

When all of the shortening has drained, scrape or brush the
sides and the bottom of the frypot.


6.

Rinse the frypot as follows:
Standard 322, 323, & 324 Open fryers

a. Close the drain valve.

DRAIN VALVE HANDLE FILTER VALVE HANDLE

b. Position return line over empty frypot.

c. Move the pump switch to the pump position.

d. Fill the frypot 1/3 full, then turn off pump.

e. Wash down and scrub the sides of the frypot with

the

brushes.

f.

After the sides and bottom are cleaned, open the

drain

valve.


321 Open fryers-After April, 2002

a. Close the drain valve. Figure 3-3.

b. Open the filter valve. Figure 3-3.

c. Move the pump switch to the pump position.

d. Fill the frypot 1/3 full, then turn off pump.

e. Wash down and scrub the sides of the frypot with

the

brushes.

FILTER UNION FEMALE QUICK-

f.

After the sides and bottom are cleaned, open the

DISCONNECT

drain

valve.

Figure 3-3

IF THERE ARE AIR BUBBLES COMING UP

IN THE SHORTENING BEFORE ALL

SHORTENING IS PUMPED UP, IT’S POSSIBLE

THAT THE FILTER CONNECTION AT THE

UNION ON THE FILTER TUBE IS NOT

TIGHTENED PROPERLY. IF SO, TURN

OFF THE PUMP AND WEAR PROTECTIVE

GLOVES OR CLOTH WHEN TIGHTENING

THE UNION. THIS UNION WILL BE HOT.

SEVERE BURNS COULD RESULT.