1.

Connect the female quick disconnect, that is attached to the

hose in the rear of the open fryer, to the correct male quick

disconnect at the wall. Once attached, the hose can remain

connected unless the open fryer is moved.

Figures 3-8 & 3-9.

The hose is to be attached to shortening return

line only for the system to work properly.

Figure 3-8

2.

Open the drain valve and drop the shortening from the

desired frypot, into the filter drain pan.

3.

Pull diverter-handle towards you, in the back of the fryer,

from FILTER to DISCARD. Figure 3-10.

This handle could be hot! Use protective gloves or

Figure 3-9

cloth when turning diverter-handle, or burns could

result.

4.

Once all shortening is gone from frypot, turn the filter

pump switch to the ON position. Shortening is now

pumped from the filter drain pan.