3-19. HIGH TEMPERATURE
LIMIT CONTROL

This high temperature control is a safety, manual reset

control, which senses the temperature of the shortening. If

the shortening temperature exceeds 425

F (218C), this

switch opens and shuts off the heat to the frypot. When the

temperature of the shortening drops to a safe operation limit,

the control must be manually reset by pressing the red reset

button. The red reset button is located under the control

panel, in the front of the fryer. Figure 3-12. This allows heat

to be supplied to the frypot once again.

Figure 3-12

3-20. REGULAR MAINTENANCE As in all food service equipment, the Henny Penny Open

Fryer does require care and proper maintenance. The table

below provides a summary of scheduled maintenance

procedures to be performed by the operator.


Procedure

Frequency

Filtering of shortening

Daily (3-4 loads)

See Filtering of Shortening

section

Changing of shortening

When shortening smokes,

foams up violently, or tastes

bad

Changing the filter envelope After 10-12 filterings, or

when envelope is clogged

with crumbs. See Changing

the Filter Envelope section


Cleaning the frypot

Every change of shortening.

See Cleaning the Frypot

section

If moving fryer to perform preventive maintenance:

• Gas supply should be turned off to avoid fire

or explosion.

• Electrical supply should be unplugged or wall

circuit breaker turned off to avoid electrical

shock.

3-28