6-1. INFORMATION MODE

Press to view the No Connect/Ground (“NC/GND”)

FUNCTIONS

(Continued)

status of each output. This monitors a possible problem with

the relays on the output PC board.


“F

√”, “H √” and “P √” in the display means everything on

the output PC board is good. A flashing “X” behind the F, H

or P means a problem exists.


Press to view the outputs and inputs (see step 10) together.


Press to continue onto the OIL TMP reading.


8. OIL TMP

This step shows the present peanut shortening temperature.

The display shows “7. OIL TMP (temp.)”.


Press to continue onto the CPU TMP reading.


9. CPU TMP

This step shows the present PC board temperature.


Press to continue on to the ANALOG reading.


10. ANALOG <1> 2.86V

This step displays the present status of any channel of the

controller’s a to d converter. This feature may be useful to a

technician troubleshooting a problem with the fryer or controller.


The displayed value can be toggled between volts and bits

by pressing . If the displayed value has a decimal point,


it is voltage (0 to 5 VDC). If no decimal point is shown, the

value is a-to-d bits (0 - 4095).


Press to continue onto AUTOLIFT/DETECT.


10. AUTOLIFT/DETECT=

This step shows the status of the autolift system, if installed.

The display indicates “Detect=Yes” if an autolift system is

detected; otherwise, it displays “Detect=No”.


The letter following the “L” indicates the status of the left- side

autolift

motor: “u” = up, “d” = down. Similarly, the letter

following the “R” indicates the status of the right-side autolift

motor.