Model OFE/OFG-321,322,323,324


Technical Data for CE/AGA Marked Products

Nominal Heat Input:

Natural (I

2H

) = 24.9 KW (85,000 Btu/h)

(Net)

Natural (I

2E

) = 24.9 KW (85,000 Btu/h)

Natural

(I

2E

+) = 24.9 KW (85,000 Btu/h)

Natural

(I

2L

) = 24.9 KW (85,000 Btu/h)

Liquid Propane (I

3P

) = 24.9 KW (85,000 Btu/h)


Nominal Heat Input:

Natural (I

2H

) = 27.7 KW (99.70 MJ/h) (94,500 Btu/h)

(Gross) Natural

(I

2E

) = 27.7 KW (94,500 Btu/h)

Natural

(I

2E

+) = 27.7 KW (94,500 Btu/h)

Natural

(I

2L

) = 27.7 KW (94,500 Btu/h)

Liquid Propane (I

3P

) = 27.7 KW (99.70 MJ/h) (94,500 Btu/h)


Supply Pressure:

Natural (I

2H

) = 20 mbar (2.0 kPa)

Natural

(I

2E

) = 20 mbar

Natural

(I

2E

+) = 20/25 mbar

Natural

(I

2L

) = 25 mbar

Liquid Propane (I

3P

) = 30 mbar

Liquid Propane (I

3P

) = 37 mbar (3.7 kPa)

Liquid Propane (I

3P

) = 50 mbar (5.0 kPa)


Test Point Pressure:

Natural (I

2H

) = 8.7 mbar (0.87 kPa)

Natural

(I

2E

) = 8.7 mbar

Natural

(I

2E

+) = 8.7/10 mbar

Natural

(I

2L

) = 10 mbar

Liquid Propane (I3P) = 24.5 mbar (2.5 kPa)



Injector Size:

Natural (I

2H

) = 3.26 mm

Natural

(I

2E

) = 3.26 mm

Natural

(I

2E

+) = 3.26 mm

Natural

(I

2L

) = 3.26 mm

Liquid Propane (I

3P

) = 1.93 mm


Restrictor Size:

Natural (I

2E

+) = 4.6 mm



This appliance must be installed in accordance with the manufacturer’s instructions and the regulations
in force and only used in a suitably ventilated location. Read the instructions fully before installing or
using the appliance.




Advertising