Henny Penny OEA/OGA-323 User Manual

Page 67

Advertising
background image

Model OFE/OFG-321,322,323,324





6-1. INFORMATION MODE

This mode gathers and stores historic information on the

FUNCTIONS

fryer and operator’s performance. Press and


at the same time and “*INFO MODE*” shows on display.

Press or to access the steps and press to


view the statistics within each step. Information Mode is

intended for technical use, but the operator can view the

following

information:


1.

E-LOG - last 11 errors and time they occurred

2.

LAST LOAD-L - information about the most recent

Cook Cycle, or the cycle presently in progress, on the left

basket

3.

LAST LOAD-R - information about the most recent

Cook Cycle, or the cycle presently in progress, on the

right

basket

4.

DAILY STATS - information for the last 7 days

5.

REVIEW USAGE- information accumulated since the

last time this data was manually reset

6.

INP A_VHDSF_M - provides test of fryer inputs

7.

OUTP - shows the state of heater and pressure

8.

OIL TMP - temperature of shortening

9.

CPU TMP - temperature of PC board

10.

ANALOG - status of controller’s a-to-d converter

11.

AUTOLIFT - shows status of autolift system (if

applicable)


Press and hold to exit Information Mode at

any time, or after 2 minutes, controls automatically exit

back to normal operation.


1.

E-LOG

(error code log)

Press and “1A. (date & time) *NOW*” shows in


display. This is the present date and time.


Press and if an error was recorded, “1B. (date, time, and


error code information)” shows in display. This is the latest

error code that the controls recorded.

1005

6-1