Henny Penny OEA/OGA-323 User Manual

Page 60

Advertising
background image

Model OFE/OFG-321,322,323,324



4-3. SPECIAL PROGRAM

6 Product Controls Only

MODE (Continued)

Enable 2 products Per Button (SP-13)

This mode is an option that allows the operator to be

able to program 2 product times on each button.

a.

Follow steps 1 and 2 above.

b.

Press the PROG button until “SP-13” and “ENABLE 2

PRODS PER BTN?” show in the display. “YES” or
“NO” shows on the right side of the display.

c.

Press and release the UP and DOWN arrows to toggle

between “YES” and “NO”. If “NO” is displayed, only
one product may be programmed per each product
button. If “YES” is displayed, two products may be
programmed per each product button. They will be
displayed as “1A”, “1B”, “2A”, “2B” etc.

12

Product

Controls

Only

Number

of

Baskets

(SP-13)

This allows the operator to set the controls for use of 1

basket

or

2.


a. Follow steps 1 and 2 above.

b. Press PROG until “SP-13” and “NUMBER OF

BASKETS” show in the display.

c. Press the UP or DOWN buttons to toggle between

“1,BSKT”,

or

“2,BSKT”.


6 Product Controls Only

Active Quality Timers (SP-14)


a. Follow steps 1 and 2 above.

b. Press PROG until “SP-14” and “ACTIVE QUALITY

TIMERS” show in the display. “NORMAL” or

“DUAL” shows on the right side of the display.

c. Press the UP or DOWN buttons to select “NORMAL”

or “DUAL”. “NORMAL” allows only one quality

timer to run at a time. “DUAL” allows 2 quality

timers

to

run

simultaneously.


12 Product Controls Only

Auto-lift

Detection

(SP-14)

a. Follow steps 1 and 2 above.

b. Press PROG until “SP-14” and “AUTOLIFT” show

in

the

display.

c. Keep the controls set at “1,DETECT” for the controls

to automatically detect the auto-lift or not.