Henny Penny OEA/OGA-323 User Manual

Page 64

Advertising
background image

Model OFE/OFG-321,322,323,324




SECTION 5. TROUBLESHOOTING

5-1. TROUBLESHOOTING GUIDE

Problem Cause

Correction


POWER switch ON but fryer

• Open circuit

• Plug fryer in

completely inoperative

• Check breaker or fuse at supply

box

Shortening will not

• Open high limit

• Reset high limit per

heat but lights are on

circuit

High Temperature Limit

Error message “E-10”

Control section

• Drain valve open

• Turn drain valve handle to

Error message “E-15”

closed position



Foaming or boiling

• Water in shortening

• At end of cook cycle, drain

over of shortening

shortening and clean

• Improper or bad

• Use recommended shortening

shortening


• Improper filtering

• Refer to the procedure covering

filtering the shortening


• Improper rinsing after

• Clean and rinse the frypot, then

cleaning the fryer

dry thoroughly


Shortening will not

• Drain valve clogged

• Open valve, force cleaning

drain from frypot

with crumbs

brush through drain


Filter switch ON but

• Motor thermal

• Reset thermal switch per section

motor does not run

protector tripped

on Filter Pump Motor

Protector – Manual Reset


More detailed troubleshooting information is available at 1-800-417-8405 or 1-937-456-8405.