Model OFE/OFG-321,322,323,324



3-12. FILTER PUMP PROBLEM

To help prevent filter pump problems:

PREVENTION

1.

Properly install paper envelope over the filter screens.
Fold the open end of the envelope, and clamp with retaining
clips so that crumbs cannot enter. Figure 3-6.

2.

Pump shortening, until no shortening is coming from the
nozzle.

Figure 3-6

3-13. FILTER PUMP MOTOR

In the event it overheats, the filter pump motor is equipped with a

PROTECTOR – MANUAL RESET

manual reset button located on the rear of the motor. After

waiting 5 minutes to allow the motor to cool, press the reset

button. It takes some effort to reset the motor. A screwdriver can

be used to help press reset button. Figure 3-7.


Servicing of the filter pump is done at the rear of the unit. If

service is required, disconnect the open fryer from the electrical

and/or gas power source, and pull the open fryer out from the

wall to gain access to rear.

Figure 3-7

To prevent burns caused by splashing shortening, turn

the unit's filter PUMP switch to the OFF position

before resetting the filter pump motor’s manual reset

protection

device.

3-14. CHANGING THE FILTER

The filter envelope should be changed after 10-12 filterings or

ENVELOPE

whenever it becomes clogged with crumbs. Proceed as follows:



The filter union could be hot. Wear protective glove or

cloth, or severe burns could result.


Use care to prevent burns caused by splashing of hot

shortening.


1.

Move the main POWER switch to the OFF position.


2.

Disconnect the filter union and remove the filter drain

pan from beneath the frypot.

703

3-21

Advertising