Henny Penny OEA/OGA-323 User Manual

Page 47

Advertising
background image

Model OFE/OFG-321,322,323,324



5.

Once all the shortening is out of the filter drain pan, turn the

filter pump switch to the OFF position.



6.

Push diverter-handle, in the back of the fryer, from

DISCARD to FILTER. Figure 3-11.


7.

Frypot is now ready for fresh shortening.

Figure 3-11

To light burner:


1. 1.

Turn the power switch to the OFF position.


2.

Rotate the gas control valve knob clockwise to the OFF

position and wait at least 5 minutes before continuing to

the next step.


3.

Rotate gas control valve counterclockwise to the ON

position.


4.

Place the power switch to the ON position.


5.

The burner will light and operate in a Melt Cycle

until the shortening reaches a preset temperature.

6.

Press the desired product button after the READY LED

illuminates.

To shutdown burner:


1.

Turn the power switch to the OFF position.


2.

Rotate gas control valve knob to the OFF position.


This fryer is equipped with a grounded (earthed) cord and plug for

your protection against shock, and should be plugged into a 3

prong grounded (earthed) receptacle. Do not cut or remove

grounding

prong.



208

3-27

3-17. OPERATING INSTRUCTIONS

FOR OPTIONAL DIRECT-
CONNECT SHORTENING
SYSTEM (Continued)

3-18. LIGHTING AND

SHUTDOWN OF THE
BURNERS

Advertising