Henny Penny OEA/OGA-323 User Manual

Page 56

Advertising
background image

Model OFE/OFG-321,322,323,324



4-3. SPECIAL PROGRAM

i. Press the UP or DOWN buttons to toggle from “NO” to

MODE (Continued)

“YES”. If “YES” is in the display, then during a time of

low volume, the operator can press the P6 button

(or P12) to manually enter the Idle mode.

Programming the idle on auto-lift open fryers, disables

the basket lift function of the P12 button.


Filter Tracking Enabled (SP-9)

The controls can be set to signal the operator when the

shortening needs filtering. The filter tracking must be

enabled to program the number of cook cycles between

filtering procedures. (See Filter Cycles in Product

Program

section.)

a. Follow steps 1 and 2 above.

b. Press and release the PROG button until “SP-9”

and “FILTER TRACKING ENABLED” flash on the

display, along with “1,OFF” on the right side of

the display.

c. To enable the filter tracking, press either the UP or DOWN

buttons to toggle the display from “1,OFF”, to

“2,MIXED”, “3,GLOBAL”, or “4,SCHED”

The “MIXED" option allows the operator to set

different amounts of Cook Cycles, between filters, for

each product. If the operator wants to have one setting

for all products, go to step g.


MIXED

d. If “2,MIXED” is selected, press the PROG button and

”SP-9A” shows in the display followed by

“SUGGEST FILTER AT …” and a value between 75%

and 100% on the right display. Press and release the

UP and DOWN arrows to change this value.





4-8 1005