Model OFE/OFG-321,322,323,324




5-2. ERROR CODES

In the event of a control system failure, the digital

display shows an error message. The message codes

are shown in the DISPLAY column below. A constant

tone is heard when an error code is displayed, and to

silence this tone, press any button.



DISPLAY

CAUSE PANEL

BOARD

CORRECTION


“E-4”

Control board

Turn switch to OFF position, then turn switch back to ON;

overheating

if display shows “E-4”, the control board is getting too hot;

check the louvers on each side of the unit for obstructions

“E-5”

Shortening

Turn switch to OFF position, then turn switch back to ON;

overheating

if display shows “E-5”, the heating circuits and temperature

probe should be checked


“E-6A”

Temperature

Turn switch to OFF position, then turn switch back to ON;

probe open

if display shows “E-6A”, the temperature probe should be

checked; to replace, refer to Technical Manual


“E-6B”

Temperature

Turn switch to OFF position, then turn switch back to ON;

probe shorted

if display shows “E-6B”, the temperature probe should be

checked; to replace, refer to Technical Manual

“E-10”

High limit

Reset the high limit by manually pushing up on the red

reset button; if high limit does not reset, high limit must be

replaced; refer to Technical Manual

“E-15”

Drain switch

Close drain, using the drain valve handle. If display still

failure

shows “E-15”, check the drain microswitch; refer to

Technical

Manual


“E-41”,

Programming

Turn switch to OFF, then back to ON; if display shows any

“E-46”

failure

of the error codes, try to reinitialize the control (Special

Program Mode section); if error code persists, replace the

control board; refer to Technical Manual

“E-20A”

Air pressure

Press the Timer button to try the ignition process again;

switch failure

if “E-20A” persists check the air switch; refer to

(stuck

closed)

Technical

Manual

“E-20B”

Draft fan or

Press the Timer button to try the ignition process again;

air pressure

if “E-20B” persists, check the air switch or the blower

switch failure

motor; refer to Technical Manual

(stuck

open)