Removal and Replacement

C4699Ć90000

3 Use the right cam journal to lift the

pinchĆwheels, and let the roller drop into

place.

4 Ensure that the bearing assembly at the

right end of the drive roller is seated in

the right sideplate and completely on the

right side of the axial bias plate.

5 Replace the overdrive clips underneath

the media separator.

6 Replace the media mount.

Press down on the media mount as you

replace the three screws. This is to ensure

correct spacing between the drive roller

and the cartridge nozzles.

Press down here as

you tighten screws

MediaĆmotor mount

Torx-20

Calibration: Perform the accuracy

calibration after reassembling the plotter.

(Details ' chapter 7.)